July 07, 2005
Airborne Ultrasound Tip
Vacuum or In-Leakage Detection
Vacuum (in-leakage) leaks are internal and sometimes these leaks can be found using isopropyl alcohol, de-mineralized water or a liquid agent your system can accept and applying it to the piping surface or suspect area while using an ultrasonic contact probe touching the suspect area. The sound will be that of bubbles popping or a “Rice-Krispies” sound. This application is great on autoclaves, sterilizers, condensers, etc…
Tip provided by Jim Hall
Ultra-sound Technologies Inc.
Vendor Neutral Ultrasound Training
http://www.ultra-soundtech.com
July 07, 2005
Distance Learning Infrared Thermography Courses
Infraspection Institute
Distance Learning Infrared Thermography Courses
Now you can receive infrared training wherever and whenever it’s convenient for you.
Our broad range of Distance Learning Courses includes Certification Prep, Applications, and Industry-Specific courses. All courses are taught by expert Level 3 instructors utilizing dynamic, multi-media resources.
Become an Infraspection Institute Certified Infrared Thermographer®. Complete 32 hours of Distance Learning and take your certification exam at one of our convenient locations.
July 07, 2005
Alignment Tip
Laser System Lens Cleaning
Always use an optical quality micro-fiber lens cleaning cloth to avoid scratching the polarized coatings of your sensor lens. These are also ideally suited at sucking fingerprints and dust right off the lens surface.
Avoid using lint-laden cotton cloths or tissues.
Tip provided by LUDECA, INC.
ALIGNMENT * VIBRATION * BALANCING
http://www.ludeca.com
Tel: 305-591-8935
July 07, 2005
Inventory and Purchasing Maintenance Tip
Inventory and Purchasing Maintenance Tips to
Enhance Maintenance Planning and Scheduling
(Tip 5 of 6 in a series) Archived at
http://maintenancetalk.com/blog.php/tipsblog
Spare Parts Storage – Proper Storage Locations
While a previous maintenance tips dealt with identifying storage locations, this tip will focus on the right type of location. Many companies fail to give the storage condition of spare parts the proper consideration. When they are ready to use the spare parts, they find that they are either defective or have been sufficiently damaged in storage and they will no longer deliver their full service life. Comfier one common example: rolling element bearings. While, many companies rely on supplier arrangements to eliminate storing bearings, they will still find bearings stored in the storeroom in major spares such as pumps, gear cases and motors.
• When examining the storage conditions for bearings, what is found in the storeroom?
• Are the locations, clean and humidity controlled?
• Are the bearings still sealed in the original containers?
• Are the bearings located in an area that is free from external sources of contamination and vibration?
In many cases, the bearings have been opened and checked by someone who was not sure of the OEM number and wanted to physically compare the bearings. In this case, unless the bearings are re-packaged, they are being damaged. The exposure to atmospheric conditions, acid in the skin of the technician, and other conditions will quickly deteriorate the life of a bearing. Even if the bearings are stored as part of a component in a spare part assembly, they will incur damaged if the storage conditions are not monitored. For example, if the bears are stored, mounted under load and not rotated, external vibration may cause a problem with false brinnelling.
Other power transmission components, such as v-belts, roller chain and gears also must be stored under proper conditions to insure their full service life when installed.
It is only when spare parts are stored in easy to find locations, where they are properly stored and protected that they will deliver their design life expectancy, keeping maintenance spare parts cost at a minimum level.
Tip provided by Terry Wireman
GenesisSolutions
http://www.GenesisSolutions.com
Tel: (203) 431-0281
June 30, 2005
5th EPRI Conference on International Maintenance - Hosted by PSE&G
August 8 - 10, 2005
Jersey City, NJ, USA
The electricity generation industry is continuing the rapid changes of the last five or more years from a stable, predictable past, to a future of competition, changing ownership, and dynamic new business goals. Adding to this new challenge, we are faced with the loss of long-term employees along with their knowledge. Many companies have mortgaged their human assets hoping to succeed in bridging the gap in knowledge and training without having developed a contingency plan.
The Electric Power Research Institute (EPRI) has structured this conference to provide some of the latest work being accomplished in the area of business evolutionary ideas, technology updates to forge ahead with more effective and efficient methods of completing maintenance work, as well as the ability to more accurately project what work has to be accomplished and when. This conference is structured for both the tactical maintenance needs as well as strategic ideas for focusing the future changes to be more successful.
June 30, 2005
Hydraulic Tip
Hydraulic System Preventive Maintenance Process that Works - “Maximize the Reliability of your Hydraulic System”
Preventive maintenance (PM) of a hydraulic system is basic and simple and, if followed properly, can eliminate most hydraulic component failure. PM is a discipline and must be followed as such in order to obtain results (A PM program should managed as a “controlled experiment”). We must view a PM program as performance oriented rather than activity oriented. Many organizations have good PM procedures, but do not require maintenance personnel to follow them or hold the personnel accountable for the proper execution of these procedures.
As in all PM programs, we must write procedures required for each PM task. These steps or procedures must be accurate and understandable by all maintenance personnel from entry level to master level.
PM procedures must be part of the PM job plan that includes tools or special equipment required to perform the task, parts or material required to perform the procedure with store room number, safety precautions for this procedure, and environmental concerns or potential hazards.
Preventive maintenance tasks for a hydraulic system could include the following:
– Change the return or pressure hydraulic filter
– Obtain a hydraulic fluid sample
– Filter hydraulic fluid
– Check hydraulic actuators
– Clean the inside of a hydraulic reservoir
– Clean the outside of a hydraulic reservoir
– Check and record hydraulic pressures
– Check and record pump flow
– Check hydraulic hoses, tubing, and fittings
– Check and record voltage reading to proportional or servo valves
– Check and record vacuum on the suction side of the pump
– Check and record amperage on the main pump motor
– Check machine cycle time and record.
Preventive maintenance is the core support that a hydraulic system must have in order to maximize component and life and reduce system failure. PM procedures that are written properly and followed properly will allow equipment to operate to its full potential and life cycle. The process allows a maintenance department to control a hydraulic system rather than the system controlling the maintenance department. We exercise control by deciding when we will perform maintenance and how much money we will spend.
The alternative is breakdown maintenance at a much higher cost.
Tip provided by Ricky Smith CMRP
MAXZOR
843-762-3168
http://www.success-in-training.com
June 30, 2005
Des-Case launches DoublePlay™ & TriplePlay™ breathers
Keeping contamination under control.
At Des-Case, we understand the importance of fluid cleanliness and the role it plays in reliability optimization. That’s why we have pioneered breather solutions specific to your industry applications that help maintain oil quality and maximize your equipment reliability.
The Des-Case DoublePlay and TriplePlay breathers are designed to filter out particles and block water in its liquid state from entering fluid containing reservoirs. The TriplePlay offers the added feature of an oil coalescing layer to prevent oil mist from entering the work environment.
Provides the ideal solution for low humidity applications; continuous operations with frequent washdowns; and arid, high dust environments.
Also offers excellent protection for water-based fluids.
Features/Benefits:
• Creates an impenetrable barrier against water droplets
• Pleated element provides a large surface area and is 99.5% efficient in blocking particles 1µ and larger
• Coalesces oil mist, preventing contamination of working environment (TriplePlay only)
• Visual vacuum indicator option actuates when maximum restriction has been reached
• Rugged ABS plastic housing
• Easy installation requires hand tighten only
To learn more please call Des-Case Technical Support 615.672.8800 or…
June 30, 2005
Vibration Analysis Tip
Remember to adjust the window factor on your analyzer. Different window factors work better for different tests. For instance, if you’re going to conduct an impact test, switch to a uniform window. This offers good frequency certainty and is ideal for transient equipment.
Tip provided by LUDECA, INC.
ALIGNMENT * VIBRATION * BALANCING
http://www.ludeca.com
Tel: 305-591-8935
June 30, 2005
EnterpriseOne Condition-Based Maintenance
Oracle’s JD Edwards EnterpriseOne Condition-Based Maintenance (CBM) enables you to make maintenance decisions based on actual equipment condition, rather than time or usage interval. You can identify equipment problems early, when they are less costly to correct, and perform maintenance only when needed, thereby increasing asset utilization, extending equipment life, and reducing maintenance costs.
JD Edwards Condition-Based Maintenance is part of Oracle’s JD Edwards EnterpriseOne Asset Lifecycle Management family of applications.
June 30, 2005
Ultrasonic Tip
Arcing inside switch gear
Corona, arcing, and tracking are ultrasound-producing phenomena that can be heard directly through the panels without opening the doors and exposing the operator to high voltage. Panels are typically NOT hermetically sealed meaning that ultrasound will pass through the edges of the panel where air gaps exist. Ultrasound, like audible sound, needs any medium to transport itself. That medium can be air, steel, or both. Arcing produces a high frequency ultrasonic signal that is airborne, but when it comes in contact with the metallic surface of the switch gear a portion of that signal is refracted through to the other side. Detecting that signal can be done with an airborne sensor or with a contact magnetic sensor placed directly on the panel. A quiet panel will read 0-5 dBuV while a fault will register 10+dBuV. Listen for sharp buzzing sounds that start and stop, grow loud and then stop.
Tip provided by SDT North America
(905) 349-2020 Tel
http://www.sdtnorthamerica.com